CFCMJ - 831 1490, KODAK K-LAB FIRST DEVELOPER REPLENISHER, PROCESS
- MSDS: CFCMJ
- Manufacturer: EASTMAN KODAK
- Product Name: 831 1490, KODAK K-LAB FIRST DEVELOPER REPLENISHER, PROCESS
- National Stock Number: 6750-00D006260
Product Identification
Product ID:831 1490, KODAK K-LAB FIRST DEVELOPER REPLENISHER, PROCESS
MSDS Date:03/06/1996
FSC:6750
NIIN:00D006260
Kit Part:Y
MSDS Number: CFCMJ
Responsible Party
US
Emergency Phone: 716-722-5151/800-242-2424
Info Phone: 716-722-5151/800-242-2424
Cage: 5K871
Contractor
Telephone: 800-828-6203
Cage: 5K871
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 90-95%
SODIUM SULFITE
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 5-10%
SODIUM CARBONATE
CAS: 497-19-8
RTECS: VZ4050000
Fraction By Weight: 1-5%
OSHA PEL 1-5 ESTABLISHED
SODIUM BICARBONATE
CAS: 144-55-8
RTECS: VZ0950000
Fraction By Weight: <1%
HYDROQUINONE (SARA 302/313) (CERCLA)
CAS: 123-31-9
RTECS: MX3500000
Fraction By Weight: <1%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:TLV: HYDROQUINONE: 2 MG/M3
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-EXPECTED TO BE A LOW HAZARD
FOR RECOMMENDED HANDLING. EYES-CAUSES IRRITATION. SKIN-CAUSES
IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION. INGESTION-EXPECTED TO
BE A LOW INGESTION HAZARD.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALATION-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS OCCUR. EYES-IMMEDIATELY FLUSH WITH PLENTY OF
WATER FOR 15 MIN. GET MEDICAL ATTENTION. SKIN-IMMEDIATELY REMOVE
SOLIED CLO THES/SHOES & WASH WITH SOAP & WATER. GET MEDICAL
ATTENTION. INGESTION-DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL
ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT MATERIAL,
THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE
THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:IMPERVIOUS GLOVES SHOULD BE WORN.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:EYE BATH, WASHING FACILITIES, SAFETY SHOWERS.
WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
MAY CAUSE ALLERGIC SKIN REACTION.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18 MMHG
Vapor Density:0.6
Spec Gravity:1.06-1.07
pH:9.6-.8
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, ODORLESS.
Percent Volatiles by Volume:90-95
Stability
Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:STABLE.
Hazardous Decomposition Products:NONE.
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL IS SUBJECT TO
NATIONAL, STATE OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE AMOUNTS OF
WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.