CFCMJ - 831 1490, KODAK K-LAB FIRST DEVELOPER REPLENISHER, PROCESS

  • MSDS: CFCMJ
  • Manufacturer: EASTMAN KODAK
  • Product Name: 831 1490, KODAK K-LAB FIRST DEVELOPER REPLENISHER, PROCESS
  • National Stock Number: 6750-00D006260
Product Identification

Product ID:831 1490, KODAK K-LAB FIRST DEVELOPER REPLENISHER, PROCESS
MSDS Date:03/06/1996
FSC:6750
NIIN:00D006260
Kit Part:Y
MSDS Number: CFCMJ

Responsible Party
EASTMAN KODAK
RODCHESTER, NY 14650
US

Emergency Phone: 716-722-5151/800-242-2424

Info Phone: 716-722-5151/800-242-2424

Cage: 5K871

Contractor
EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
ROCHESTER, NY 14650-3129 US

Telephone: 800-828-6203

Cage: 5K871

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 90-95%


SODIUM SULFITE

CAS: 7757-83-7

RTECS: WE2150000

Fraction By Weight: 5-10%


SODIUM CARBONATE

CAS: 497-19-8

RTECS: VZ4050000

Fraction By Weight: 1-5%

OSHA PEL 1-5 ESTABLISHED


SODIUM BICARBONATE

CAS: 144-55-8

RTECS: VZ0950000

Fraction By Weight: <1%


HYDROQUINONE (SARA 302/313) (CERCLA)

CAS: 123-31-9

RTECS: MX3500000

Fraction By Weight: <1%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9596

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:TLV: HYDROQUINONE: 2 MG/M3
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-EXPECTED TO BE A LOW HAZARD
FOR RECOMMENDED HANDLING. EYES-CAUSES IRRITATION. SKIN-CAUSES
IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION. INGESTION-EXPECTED TO
BE A LOW INGESTION HAZARD.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS OCCUR. EYES-IMMEDIATELY FLUSH WITH PLENTY OF
WATER FOR 15 MIN. GET MEDICAL ATTENTION. SKIN-IMMEDIATELY REMOVE
SOLIED CLO THES/SHOES & WASH WITH SOAP & WATER. GET MEDICAL
ATTENTION. INGESTION-DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL
ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT MATERIAL,
THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE
THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:IMPERVIOUS GLOVES SHOULD BE WORN.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:EYE BATH, WASHING FACILITIES, SAFETY SHOWERS.
WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
MAY CAUSE ALLERGIC SKIN REACTION.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18 MMHG
Vapor Density:0.6
Spec Gravity:1.06-1.07
pH:9.6-.8
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, ODORLESS.
Percent Volatiles by Volume:90-95

Stability

Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:STABLE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL IS SUBJECT TO
NATIONAL, STATE OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE AMOUNTS OF
WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.